Medigate

Auto Refractor / Auto Refractometer

MG-9000 TOP QUALITY AUTO REFRACTOMETER, AUTOREFRACTORS
SPECIFICATION:
Measurement Range Sphere -20d~+20d (Vd=12mm) 0.125d/0.25d Steps
Cylinder -8d~+8d 0.125d/0.25d Steps
Axis Angle 1°~180° 1°Steps
Pupillary Distance 45~85mm 1mm Steps
Vertex Distance 0/12/13.75/15mm
Minimum Pupil Diameter ¢2.0mm
Chart Auto Fog Chart
Date Saving 10 Measured Values For Both Eyes
Specification Display: 5.7" Lcd(Color)
Print: Built-In Thermal Printer
Power Suppiy: Ac 220v ,50hz Or 110v, 60hz
Dimensions/Weight: 288(W)*500(D)*480(H) 14kg
Output:Rs-232
Power Save:5/10 Min (Selectable)

SLIT LAMP OPTICARE

Technical Data

o There are iphone or Sumsung mobile adapter optional, can take images by mobile.
o Type Parallel Galilean
o Eyepiece 12.5X
o Total Magnification 6X, 10X, 16X, 25X, 40X
o Diameter of Visual Field Φ 37, Φ 23, Φ 14, Φ 8.7, Φ 5.7mm
o Diopter Adjustment +5D–5D
o Slit Width 0mm-14mm continuously adjustable
o Slit Height 1mm-14mm continuously adjustable
o Aperture Diameter Φ 14, Φ 10, Φ 5, Φ 3, Φ 2, Φ 1, Φ 0.2mm
o Slit Angle 0° -180°
o Illumination Tilting 0° , 5° , 10° , 15° , 20°
o Filter Heat absorption, grey, redfree(green), cobalt blue
o Lamp: German OSRAM Halogen Tungsten Lamp
o Longitudinal movement: 90mm
o Lateral movement: 100mm
o Vertical movement: 30mm
o Fine base movement: 15mm
o Input Voltage 110V/220V 60/50Hz
o Input Power 60VA
o Illumination Bulb 12V/50W halogen bulb, led lamp optional
o Fixation Red LED

OPHTHALMIC OCT (OCT-500) OPTICARE

Technical Data Built-in computer
Simple, fast and easy to operate

Posterior segment OCT. The OCT is an ophthalmic optical coherence tomography scanner tailored for rapid screening of fundus diseases in outpatient clinics. It is easy to use, clear in image, smooth and delicate in operation, and equipped with professional analysis software to meet the requirements of OCT in the clinical examination and analysis of ophthalmology.

Features:

1.Compact Design: Everything is inside this compact body. No external computer is needed. Plug in the power cable, then you are ready to go.
2.PC Inside: Data acquisition and processing are accomplished by the internal computer. The data can be transported via ethernet or external harddrive. Peripheral devices, such as keyboard or printer, can be connected to the computer ports.
3.Easy Installation: No complex connection or setup. Compact body can fit in even small space.

Methodology Spectral domain OCT
Axial resolution ≤ 6 µm (in tissue)
Transverse resolution ≤ 20 µm (in tissue)
Scan depth ≥ 6 mm
Scan speed ≥ 24,000 A-scans/sec, up to 36,000 A-scans/sec
Scan modes 30, Raster, Circle
Fundus image OCT en face
Focus adjustment -150 to +150
Pupil diameter ≥ 3 mm
OCT light source 840 nm SLD
Optical power 750 µW (at cornea)
Operation 13.3''touch screen, optional external mouse or keyboard
Power supply 100-240 V, 50/60 Hz
Dimensions 497 mm × 395 mm × 490 mm (L× W × H)
Weight LED dot matrix
External Fixtion 34 kg (75 lbs)

A/B SCAN

Ophthalmic AB Scan.AB-1000-OPTICARE
Feature:

1).12.1″ color and touch screen.
2). With the same software as Quantel, top one in China With advanced intelligent digital software and parameters of freezed and Stored images could be adjusted voluntarily.
3). Can have different results on the report according to different constants A Scan A measures data for every part of the eyeball as anterior chamber depth, lens thickness axial length and so on which are needed in ophthalmic surgeries, and calculates IOL by axial length.
4). B scanner use electromagnetic, better save B probe life. Scan B displays profile images of the eyeball clearly and directly. Scanning anatomical forms and nidi inside the eyeball, doctors can diagnose accurately for examination of cataract, vitreous body disease, ocular trauma, detachment of retina or choroid, macula disease, and intraocular tumor, etc
5). B scanner, video playback of 100 images.
6). A scanner, one group with 10 data to get average, At the same time the accuracy is 0.05mm

TECHNICAL DATA:
A Scan biometry
Probe frequency 10MHz
Measuring mode contact
Measuring range Over 5mm-40mm
Measuring error ≤±0.05mm
Measuring type Length of optic axis , automatic calculation , result analysis auto ,
Image freezing auto+preservable, manual
Intraocular lens implantation (IOL)formula SRK-T, SRX II, HOLLADAY, BINKHORST-II, HOFFER-Q,HAIGIS
Gain 20-110dB
Time gain adjustment 0-30dB
B Scan patterns
Probe frequency 10MHz
Probing depth ≥50mm
Axial Resolution ≤0.2mm
Lateral resolution ≤0.3mm
Gain adjustment 20-110dB
Time gain adjustment 0-30dB
Operation mode Eyecup, gel, aqueous capsule
Post-processing measuring tools Area, length, mark and annotation
Review 100 images available
Size 340mm*320mm*115mm
weight 10kg
Power supply 100-240V 50/60Hz

AUTOLENSOMETER

AUTO LENS METER OPTICARE
Features:

1.Measurement of PD, PH, and PCL (progressive channel Length).
D910 Auto Lens meter
2.New capacitive touch panel with high resolution
3.The wavelength of UV and green light can be measured simultaneously .
D910 Auto Lens meter
4. Bluetooth, RS232 serial port, USB and WIFI ,4 forms of data communication
5. Better performance .Finer marking pens and lens holder. Magnetic and stable sliding nosepiece
D910 Auto Lens meter

TECHNICAL DATA:
Sphere -25.00D-+25.OOD
Axis 0°-180° (1°step)
CYLINDER 0 - ±9.99D 0.01/0.12/0.25D steps
Prism Degree 0 - 15D 0.01/0.12/0.25D steps
ADD 0 - ±9.99D 0.01/0.12/0.25D steps
Cylinder +, +/-, -
Prism X-Y, P-B
Contact lens Soft/hard
Measuring Mode Single/progressive/automatic recognition
Diameter of Lens φ12-φ112mm
PD 40~90mm, 0.5mm steps
Speed of measurement 0.1s
Display TFT LCD (7.0") 640*480
Printer Thermal Printer
Dimension 180(L) * 255(W) * 455 (H) mm
Package 620(L) * 390(W) * 390 (H) mm
Weight About 12kgs
Power Supply 100~240V 50~60H

OPTHALMIC VISUAL FIELD APS6000

Aps-6000cerTraditional Perimeter; LED
Specifications:

Aps-6000cerTraditional Perimeter; LED Specifications
Radius of stimulator: 300mm±5mm
1.Stimulating source of LED
2.Two visual lights: yellow and red.
3.Stimulating strength: From 0nt (0asb) to318.310nt (1000asb), have 14 degree to adjust, the error is±10%.
(1.)Error of background brightness: 4asb±10%
(2.)Light spot: Diameter is 2mm +/- 0.25mm.
(3.)The number of stimulating and the stimulating time:
A.388 spots (Red light: 61spots, yellow: 327spots);
B: stimulating retention time: 0.2s–2.0s, the program can adjust (±5%);
C: stimulating spacing interval: 0.5s –2.0s, the program can adjust (±5%);
4.Window of eye-position tracking: White-black CCD, directly tracking the testing eye;
5.The length of chin rest: up-down: 80mm±10%; right-left 115mm±10%Eye position tracking: When blinking, the system will alarm automatically.

TECHNICAL DATA:
Sphere -25.00D-+25.OOD
Axis 0°-180° (1°step)
CYLINDER 0 - ±9.99D 0.01/0.12/0.25D steps
Prism Degree 0 - 15D 0.01/0.12/0.25D steps
ADD 0 - ±9.99D 0.01/0.12/0.25D steps
Cylinder +, +/-, -
Prism X-Y, P-B
Contact lens Soft/hard
Measuring Mode Single/progressive/automatic recognition
Diameter of Lens φ12-φ112mm
PD 40~90mm, 0.5mm steps
Speed of measurement 0.1s
Display TFT LCD (7.0") 640*480
Printer Thermal Printer
Dimension 180(L) * 255(W) * 455 (H) mm
Package 620(L) * 390(W) * 390 (H) mm
Weight About 12kgs
Power Supply 100~240V 50~60H

AUTO KERATOMETER

OPT-V018-N OPTICARE auto refractometer with keratometer
Features:

OPT-V018-N OPTICARE auto refractometer with keratometer
• Sphere -20~+20D(VD=12) 0.125D
• Step Cylinder -8~+8D 0.125D
• Step Axis 0°~180° (1°step) PD 045-88mm,1mm
• Step VD 0mm,12mm,13.75mm
• Min Pupil Size ø2.0mm
• Keratometry Radius of curvature 5.0~10mm(increment:0.01mm)
• Comal power 33.75~67.50D(when comer equivalent refractive index is 1.337)

GREEN LASER ARGON -APPASSAMI

Specifications:

• GREEN LASER PHOTO COAGULATOR FOR RETINAL DISORDERS
• PATENTED SOLID – STATE TECHNOLOGY
• EXTENDED LIFE AND EFFICIENCY
• TRUE CONTINUOUS WAVE
• TOUCH SCREEN INTERFACE
• Special Features
• Light weight and portable.
• LCD touch screen display with mounting
option on table and also on the console. • Foot switch with LED.
• Fiber connecting port is illuminated with LED.
• Metal shielded laser delivery fiber optic cable

TECHNICAL DATA:
Model AMOGH PLUS
Treatment Laser Diode pumped, frequency doubled, true cw & solid state.
Laser Module Capacity 3 Watts
Aiming Beam 635 nm, Semiconductor diode laser,0 to 1 mW (variable)
Power Adjustment Variable from 10 to 1500 mW
Electrical Requirements 110V/230 VAC 50/60Hz, 2A, single phase
Cooling Thermo electric cooling (peltier) and air cooled
Operation Mode Repeat pulse, single pulse, continuous mode
Touch Screen Display LCD screen with feather touch
Lifetime 10,000 Working hours
Dimensions 290(H) x 175(W) x 365(D) mm
Weight 8 Kg
Power Consumption 100 Watts
Pulse Duration 0.01 – 10 Sec.
Pulse Interval 0.01 – 10 Sec.
Treatment Laser Safety Class IV